Gen3 - Software - Commission Spare Display
A spare display must be updated with the model specific configuration files before it can be used with an existing Gen3-LMS system.
If the existing display is available swap over the SD card from the spare display. This will ensure that the sensor calibrations and other logs files are transferred to the new spare display.
Installing the SD card from old display is not all that is required to commission the spare display. The remaining instructions must be followed in order to correctly commission the spare display.
The Gen3 configuration software will be used to update the configuration files on the spare display.
To perform the update a laptop with an SD card reader and internet connection is required.
The below needs to be performed off-site when the laptop has an internet connection
Download EQSS Update software
- Go to http://www.eqss.com.au in a web browser
- Click on Login in the top menu
- Type in the user name and password for your company and click Log in (contact EQSS if you don't know your company username and password)
- Click on Secure Menu in the top menu
- Click on the link EQSS Update Software Download
- Click on the link Download EQSS Update software V 1.6, to start the setup program download
- Once the download is complete run the setup program to install the software
Download the latest model files using the EQSS Update software
- Run the EQSS Update software from Start Menu -> All Programs -> EQSS -> EQSS Update -> EQSS Update
- Enter the same username and password into the User and Pass fields
- Click on Check For Updates to list the available updates
- Any new updates will automatically be ticked in the Select Updates window
- Click on Download Updates to download and install the updates
Note: It may also start the install processes for other software updates, run through the prompts to install the software - Once the downloads/installations are complete click on Quit
The below needs to be performed on-site with access to the machine
The Gen-3 Configuration Tool user manual
here or installed under Start Menu -> All Programs -> EQSS -> Gen-3 Configuration Tool explains the Gen-3 Configuration Tool in more detail and shows how to remove the SD card from the display
- Remove the SD card from the Gen3 display and insert into the laptop
- Run the Gen-3 Configuration Tool from Start Menu -> All Programs -> EQSS -> Gen-3 Configuration Tool -> Gen-3 Configuration Tool
- Click on Select SD Card, it should bring up a message saying it has found the sd card on drive X: and click OK
- Click on the Machine Model tab at the top of the screen
Note: If the SD card from the existing display is not used, then popup message will appear and transfer to the Machine Model tab automatically - Select the model file from the list that matches the machine
- Click on Save Changes
- Click on the Settings tab at the top of the screen
- Enter machine serial number into the Serial Number field
- Note: This field will already be filled if using the SD card from the existing display
- Set the Tool Recognition field to Manual or Automatic depending on if the Gen3-LMS systems uses manual or automatic tool selection
- Set the camera checkboxes depending on if the Gen3-LMS has a forward and/or reverse camera installed
- Click on Save Changes
- Click on the Attachments tab at the top of the screen
- Disable any attachments that aren't used with the machine, by selecting the attachment and clicking the Attachment Enabled checkbox
- Click on the Logo tab at the top of the screen
- Click on the Load New Logo button and select your company logo for both the Startup and Shutdown logos
- Click on Save Changes
- Return to the SD Card tab
- Click on Save to SD Card, this will bring a popup message explaining how to finish the update, click on OK
- Click Safely Remove Hardware from the system tray to safely remove the SD card from the laptop
- Insert the SD card into the Gen3 display
- Start the engine to power the Gen3 LMS
- Wait for the display to finish the software update and reboot
On the Attachments tab, if the attachment is shown in red then a load calibration of the attachment will be required before it can be used.
If an non calibrated attachment is enabled and selected in the Gen3 it will display the following in place of the load reading on the display "Gen3 Load Measuring Disabled" and will not generate a cutout if overloaded.
Related Articles
Gen3 - Software - Update Barminco ITC Display Software
There are two versions of the ITC software for the Gen3-LMS. These instructions will apply the software for the Barminco range of machines. For all other ITC machines follow the Universal software instructions here. The following instructions will ...
Gen3 - Software - Update Universal ITC Display Software
There are two versions of the ITC software for the Gen3-LMS. These instructions will apply the Universal software. If the machine is owned by Barminco follow the instructions here. The following instructions will describe copying an update file to ...
Gen3 - Software - Update Telehandler Display Software
These instructions apply for updating Gen3-LMS systems installed on Telehandlers. This update should not be applied to Gen3-LMS systems installed on ITCs or other machinery. To update the Gen3-LMS for ITC machines see the related Knowledge Base ...
Gen1 - Software - MPCT Calibrator Software
Your Gen 1 Safety System must be calibrated using a laptop and EQSS calibration software before being put into service The MPCT Software is to be loaded on a laptop and is broken down into seven calibration sections and one configuration section. ...
Gen4 - User - Display Settings
Press the display settings icon in the top right corner of the rating chart to show the display settings page. The display settings page allows the brightness and volume of the display to be adjusted. The display software version is also shown in the ...