Crush Guard - Service - Genie ALC500/ALC1000 Frame Structure

The purpose of this Tech Doc is to help with the Servicing of the frame structure
Frame
The frame is mounted to the front of the EWP and runs a steel wire rope in front of the
EWP controls. When the operator leans on the wire rope the alarm will trigger and
cutout any further movement.
Damage to Frame Structure
If there has been a heavy impact to the mechanical structure of the frame (causing the tubing to be bent out of shape) then the frame will need to be replaced. Damage
to the mechanical structure can not be repaired. For further information on removing
the frame from the EWP consult the Crush Guard installation manual for the Genie ALC500/ALC1000
model.
If the magnetic anchor, rope switch and user interface are undamaged, they can be
removed from the frame and only a replacement frame and wire will need to be
ordered.
Damage to Wire Components
If the wire (or the blue hose sheath over the wire) has been cut or damaged then it will
need to be repaired. Return the frame to EQSS to replace the wire.
Damage to Rubber Post Covers
If the rubber post covers have been cut or punctured where they are interfering with
the tension on the wire, then they will need to be replaced. Return the frame to
EQSS to replace the rubber post covers.