Crush Guard - Service - Genie ALC500/ALC1000 Adjust DIP Switches

The purpose of this Tech Doc is to help with the adjustment of the DIP switches
The control module contains two sets of DIP switches.
DIP Switch SW2 is used to customise future functionality and at the moment serves
no function. The only valid state for DIP Switch SW2 is: all four switches in the OFF
position.

Any other switch positions will generate an error.
DIP Switch SW1 is used to configure input signal polarities. SW1 is configured in the
factory to match the EWP and should not be altered in the field. Changing the
settings of SW1 can cause erroneous fault codes to be produced during operation. If
the DIP Switch settings for SW1 have been unintentionally altered contact EQSS for the correct DIP Switch settings for your model EWP.


DIP Switch SW2 must all be set to the OFF position otherwise
a fault will be produced disabling the EWP controls

DIP Switch SW1 must not be altered otherwise random faults
will be produced disabling the EWP controls
Related Articles
Crush Guard - Service - Manitou 160ATJ/180ATJ/200ATJ Adjust DIP Switches
The purpose of this Tech Doc is to help with the adjustment of the DIP switches The control module contains two sets of DIP switches. DIP Switch SW2 is used to customise future functionality and at the moment serves no function. The only valid state ...
Crush Guard - Service - Genie ALC500/ALC1000 Maintenance
The components of the Crush Guard require periodic checks and maintenance to be performed to ensure it remains in good working order. Clean the Magnetic Anchor The magnetic anchor can accumulate metallic debris. If too much debris accumulates around ...
Crush Guard - Maintenance - Service and Repairs
The section will familiarize you with the components that comprise the Crush Guard® in order to perform a service or repair. The diagram below outlines the major system components and how they interconnect. Frame The frame is mounted to the front of ...
Crush Guard - Service - Genie ALC500/ALC1000 Components Overview
This Tech Doc will familiarise you with the components that comprise the Crush Guard in order to perform a service or repair. The diagram below outlines the major system components and how they interconnect:
Crush Guard - Service - Genie ALC500/ALC1000 Frame Structure
The purpose of this Tech Doc is to help with the Servicing of the frame structure Frame The frame is mounted to the front of the EWP and runs a steel wire rope in front of the EWP controls. When the operator leans on the wire rope the alarm will ...