The user interface is mounted to the frame and contains status lights as well as an
override switch.
Damage to User Interface
If the user interface has been damaged from an impact causing a breach of the enclosure or damage to the override switch or the cable, then the user interface will need to be replaced. The user interface enclosure including the cable is a self contained unit with no replaceable parts.
Follow the instructions below to replace the user interface.
Replace User Interface
Once the replacement user interface has been ordered and received follow the instructions below to swap out the user interface.
1. Disconnect the cable from the user interface into the control module
2. Cut any cable ties and remove the rope switch cable from the snake tubing
3. Remove the cable from the p-clip, by removing the bolts on the cover of the User Interface enclosure, to access the bolt attached to the p-clip
4. Remove the remaining bolts attaching the user interface enclosure to the frame
5. Remove the bolts attaching the cover of the replacement user interface
6. Secure the replacement user interface to the frame using the existing bolts
7. Run the cable through the p-clip and reattach the p-clip to the existing location
8. Reattach the user interface cover
9. Run the cable through the snake tube, reconnect to the control module
10. Secure using cable ties