Gen3 - Calibration - Perform Attachment Calibrations
Calibration for attachments requires discipline, is time consuming and should be completed carefully.
To carefully complete an attachment calibration usually requires one to two hours of work.
The attachment calibration task requires:
1. Gen 3 Calibration Cable
2. Laptop with Windows OS
3. SD Card Reader
4. EQSS Calibration Software
5. Operational Telehandler fitted with EQSS Gen 3 system
6. Accurate known weight (typically 800Kg - 1200Kg but will depend on the machine/attachment)
This article will not go deeply into the attachment calibration process as the accompanying 'eqss Gen-3 LMS Calibration Software - User Manual' is a 41 page comprehensively written document that does a good job in guiding the user through the process. This document is automatically included when the EQSS software is installed (on the Laptop that will be used for the actual Calibration).
Download EQSS Update software
- Go to http://www.eqss.com.au in a web browser
- Click on Login in the top menu
- Type in the user name and password for your company and click Log in (contact EQSS if you don't know your company username and password)
- Click on the link EQSS Update Software Download
- Click on the link Download EQSS Update software V 1.6, to start the setup program download
- Once the download is complete, run the setup program to install the software
Download the latest model files using the EQSS Update software
- Run the EQSS Update software from Start Menu -> All Programs [All apps] -> EQSS -> EQSS Update
- Enter the same username and password into the User and Pass fields
- Click on Check For Updates to list the available updates
- Any new updates will automatically be ticked in the Select Updates window
- Click on Download Updates to download and install the updates
Note: It may also start the install processes for other software updates, run through the prompts to install the software - Once the downloads/installations are complete click on Quit
- {Manual} Open the 'eqss Gen-3 LMS Calibration Software - User Manual' - Start Menu -> All Programs -> EQSS -> EQSS Gen-3 Calibration Tool User Manual
- {Tool} Run the EQSS Gen-3 Calibration Tool - Start Menu -> All Programs -> EQSS -> EQSS Gen-3 Calibration Tool
- Begin by first executing the 'Sensors' Calibration
- Then proceed to Page 25 in the manual -- read and follow the instructions on the 'Load' - calibrating the load reading
- Continue through all of the steps until you complete [Gain Calibration - With load - Step 6]
Related Articles
Gen3 - Calibration - Perform Sensor Calibrations
Follow the instructions below to access the sensor calibration menu. Press Enter on the user control dial to enter the menu system. Press the arrow buttons to select System Menu. Press Enter to select the menu. Select Advanced Menu Enter the password ...
Gen4 - Calibration - Load Calibration Tips
This Tech Doc will offer a few suggestions to follow in order to perform an accurate calibration. The points listed below are recommended to follow for each of the calibration steps. Make sure to lower the stabilizers (if fitted) and try to level the ...
Gen4 - Calibration - Load Calibration Basic Outline
The load calibration procedure will ask the operator to calibrate the load for the attachment. The operator will be required to perform the calibration procedure for each different attachment. The first step in the procedure is to determine the ...
Gen4 - Attachments - Attachment Menu
The attachment selection menu is accessible by pressing the change attachment button in the bottom right corner on the attachment description on the main screen. The change attachment button is highlighted below. Once the new attachment is selected ...
Gen3 - Attachments - Attachment Automatic Recognition
When the Gen-3 system is configured for automatic tool selection, the system will read the identification tag on the attachment and automatically change the system to the matching attachment. If the attachment has multiple configurations (e.g. ...