N01

Gen3 - Fault Code - N01

This fault code can appear when the CCIM is not able to communicate with the Display

The permanently connected CCIM Display cable coming out of the CCIM module plugs into the rear lower 8 pin circular connector on the Display unit. All CAN bus communication between the CCIM and the Display takes place via this cable. This cable also supplies power from the CCIM to the Display.

Troubleshooting:
1. Check that there are no obvious signs of damage to both the cable and the plug that connects to the Display unit.
2. Ensure the bottom 8 pin circular connector from the display is fastened and secured to the cable connector. 
3. Using the index finger and thumb, clasp the cable near the display unit, then move the cable by rocking side to side and by rotating - whilst watching the display unit looking for any changes in the displayed fault code. If the fault code state changes (N01 disappears/reappears) with this action then an intermittent fault has been found in the cable and the CCIM should be sent back to EQSS for diagnosis/repair. 

 



    • Related Articles

    • Gen3 - Fault Code - All Gen 3 Fault codes

      Gen 3 Fault codes are displayed in Red color and are displayed in the same - on screen section as the 'Attachment' field On screen Fault codes location. Fault and fault codes are only displayed if a fault has actually occurred (blank normally). To ...
    • Gen3 - Fault Code - T05

      This fault code can appear when the Gen 3 is not able to write to the SD card. There are two common causes for this error code: 1. Write Lock Tab on the SD card has been set to 'Locked'. 2. SD card carrier in the EQSS Display unit is faulty. ...
    • Gen3 - Fault Code - T01

      This fault code can appear when a component of the Gen 3 system has been replaced and/or reprogrammed (usually the CSDM display). The remedy that usually clears this fault is the re-calibration of the boom angle. To achieve this task requires the ...
    • Gen3 - Fault Code - T03

      This fault code can appear when a component (CPIM) of the Gen 3 system has been replaced/moved and can sometimes be intermittent during telehandler operation with shifting weight. The remedy that usually clears this fault is the re-calibration of the ...
    • Gen3 - Fault Code - T02

      This fault code can appear when a component of the Gen 3 system has been replaced and/or reprogrammed. The remedy that usually clears this fault is the re-calibration of the boom length. To achieve this task requires the operator to navigate the Gen ...