This fault code can appear when a component (CPIM) of the Gen 3 system has been replaced/moved and can sometimes be intermittent during telehandler operation with shifting weight.

The remedy that usually clears this fault is the re-calibration of the carrier angle. Achieving this task requires the operator to navigate the Gen 3 menu system to the 'Calibrate Carrier Angle' function screen.

The navigation path from the Gen 3 main screen is: 
1. Press the center 'Enter' button on the 5 button user control
2. Navigate to the 'System Menu'
3. Navigate to the 'Advanced Menu'
4. Enter Password '2  -  8  -  4' and then 'Submit Password'
5. Navigate to the 'Sensor Calibrations'
6. Navigate to the 'Calibrate Carrier Angle' function

Raise the telehandler boom to 5 degrees  or so (just enough so that the attachment doesn't dig into the ground during vehicle driving). Drive the vehicle onto a flat even surface (preferably a concrete surface). The  'Calibrate Carrier Angle' screen has a 'Calibrate Angle X'  and a 'Calibrate Angle Y' readout. The ideal is for both of these parameters to read as close as possible to '0.0'. If they don't, then some minor repositioning of the vehicle (driving backwards and forwards) may yield a closer reading to '0.0' on both of the readouts. Then read and execute the instructions on the display to complete the 'Calibrate Carrier Angle'

Navigate back to the Gen 3 main screen and the T03 fault should have been cleared and no longer be displayed. If the T03 fault remains then the CPIM may have developed an electronic fault and may require factory diagnosis/repair.

If the problem persists then contact EQSS support for further guidance.


    • Related Articles

    • Gen3 - Fault Code - All Gen 3 Fault codes

      Gen 3 Fault codes are displayed in Red color and are displayed in the same - on screen section as the 'Attachment' field On screen Fault codes location. Fault and fault codes are only displayed if a fault has actually occurred (blank normally). To ...
    • Gen3 - Fault Code - T05

      This fault code can appear when the Gen 3 is not able to write to the SD card. There are two common causes for this error code: 1. Write Lock Tab on the SD card has been set to 'Locked'. 2. SD card carrier in the EQSS Display unit is faulty. ...
    • Gen3 - Fault Code - T01

      This fault code can appear when a component of the Gen 3 system has been replaced and/or reprogrammed (usually the CSDM display). The remedy that usually clears this fault is the re-calibration of the boom angle. To achieve this task requires the ...
    • Gen3 - Fault Code - T02

      This fault code can appear when a component of the Gen 3 system has been replaced and/or reprogrammed. The remedy that usually clears this fault is the re-calibration of the boom length. To achieve this task requires the operator to navigate the Gen ...
    • Gen3 - Fault Code - T14

      This fault code can appear with a fresh Gen 3 install or when a CCIM has been replaced. The EQSS CCIM uses PCB mounted DIP switch banks for forward/reverse telehandler drive logic settings. These settings are configured at the factory and can be ...