Gen3 - General - High Pressure Washing
Do NOT high pressure clean any EQSS Gen 3 components as this will void your warranty.
High pressure cleaning is only possible on IP-69 (and above) rated items. None of the EQSS components are rated to IP-69.
IP ratings for EQSS components:
6202 CSDM (Display Unit) = IP-54
6259 CCIM = IP-65
6258 CPIM = IP-67
6206 CALM (Cable Reeler) = IP-64
6231 CLTM (Light Tower) = IP-64
Third Party Supplier
OP001028 Gen 3 - Rear Camera = IP-67
OP001029 GEN3 - Forward Camera = IP-67
As can be seen, these cameras and all of our components are not high pressure cleaner proof nor even high pressure cleaner resistant. This is the reason that we provide 'No High Pressure Washing' sticker labels on all of our weather bearing gear.
If you absolutely must high pressure clean your ITC/Telehandler then please avoid pressure cleaning the installed EQSS Gen 3 components.
Water ingress on a Gen 3 component from a high pressure cleaner will render your safety system unreliable, thereby negating it's purpose and shall absolutely void your warranty.
Related Articles
Gen3 - Installation - Can Pressure Input Module (CPIM)
The CPIM is responsible for processing the information sent from the pressure sensors and also measures the carrier attitude (telehandler base angles). The CPIM is mounted on the chassis and must be mounted with the five M12 screw lock connectors ...
Gen3_ITC - General - What is it GEN 3 ITC?
This system has been designed specifically for use with Integrated Tool Carriers (ITC) to cover all relative national and international safety standards. This Tech Doc details system specifications, system functionality, installation requirements, ...
Gen3 - General - What is Gen 3 LMS?
The Gen3-LMS is a culmination of the current research and development efforts conducted by EQSS. The main purpose of the Gen3-LMS is to provide an additional level of safety when lifting both suspended and non-suspended loads. It is in effect a ...
Gen4 - General - What is Gen 4 LMS?
Hardware Overview Display The Model 6205 Display Module is the main HMI device for the Gen4-LMS. It is used to display information to the operator. It contains a built in touch screen to allow the operator to interact with the system, and dual audio ...
Gen3 - Installation - Generic Main Pressure Sensor Installation
The hydraulic pressure sensors are used to measure the lifting load of the telehandler. There are two main pressure sensors that need to be mounted to measure the pressure in the main lift cylinder - Main Head and Main Rod. Main Head Pressure The ...