Gen3 - Installation - Pressure Sensors MUST be mounted exactly as Installation Manual shows

Gen3 - Installation - Pressure Sensors MUST be mounted exactly as Installation Manual shows

Alert
Pressure Sensors MUST be mounted exactly as the Installation Manual shows in illustrations

The various pressure sensors that the EQSS relies on to monitor shifting hydraulic pressures are mounted to the key telehandler (on boom) hydraulic blocks. Unfortunately, some telehandlers don't have much clearance around the moving/working boom. This makes hydraulic sensor mounting orientation in some circumstances critical. Under those conditions, the sensors must be mounted exactly as shown in the installation manual photos. Failure to do so can result in damaged or even broken sensors. EQSS installers are aware of the tight mounting tolerances and have installed many kits with zero problems. However, third party installers do occasionally have problems. 

Below: example of critical required positioning of an EQSS sensor - sensor must be installed exactly as shown in the photo


Below: Pressure sensor mounting on various make/model telehandlers
Other JCB sensor mounting points
   

Below example: Manitou sensor mounting points

Below example: Bobcat sensor mount points
      

Below example: Haulotte sensor mount points


Room for EQSS Simplification and Improvement
Where EQSS sees an opportunity to simplify and improve a customer's experience with a kit, we do implement changes.
The critical sensor mounting example (as shown at the top) in the first photo of this Tech Doc was made less critical by including a hose extension and then moving the position where the hydraulic sensor will be mounted - somewhere out of harms way.
   

Notes
This type of change increases the component count and installation complexity slightly, but reduces the risk of accidental damage.
    • Related Articles

    • Gen3_ITC - Installation - Volvo L120H Main Head & Rod Pressure Sensors

      The hydraulic pressure sensors are used to measure the lifting load of the ITC Installation Steps: Completely lower the boom. Apply the handbrake and insert chock under wheels. Once lowered, release any residual pressure by pulling on the manual ...
    • Gen3 - Attachments - Change Between Automatic & Manual Tool Selection

      Changing settings via the display was added in Display Version 1129. Check the current display version in the Status Menu. If the version is older then follow the instructions here to update the display. Press Enter on the user control dial to enter ...
    • Gen3 - Installation - Generic Main Pressure Sensor Installation

      The hydraulic pressure sensors are used to measure the lifting load of the telehandler. There are two main pressure sensors that need to be mounted to measure the pressure in the main lift cylinder - Main Head and Main Rod. Main Head Pressure The ...
    • Gen3 - Installation - Can Pressure Input Module (CPIM)

      The CPIM is responsible for processing the information sent from the pressure sensors and also measures the carrier attitude (telehandler base angles). The CPIM is mounted on the chassis and must be mounted with the five M12 screw lock connectors ...
    • Gen3 - Installation - Installation Outline

      The diagram below outlines how the system components are connected for the Gen3 LMS. It is recommended to install the components in the following order: 1. The external sensor components, Pressure sensor adapters and pressure sensors (making sure ...