Gen3_ITC - Fault Code - IN03

Gen3_ITC - Fault Code - IN03

Notes
The CDAM (Angle Sensor) Module is a CAN bus device 

If an IN03 fault code is displayed then there is a communication error between the CPIM module and the CDAM (Angle Sensor). The IN03 fault code indicates that the CDAM is Off-line and can't be seen by the rest of the CAN bus devices.
  1. Ensure the cable running along the boom with the 4-Pin circular connectors from the CPIM to the CDAM is fastened and secured on both ends of the cable.
  2. Inspect the cable for possible damage.
  3. Replace the CDAM 
  4. Make sure that the 4-Pin sockets pins are not bent within the sockets
Info
If you suspect a faulty CDAM module then contact EQSS for further guidance
    • Related Articles

    • Gen3_ITC - Fault Code - All Gen 3 Fault codes

      Gen 3 Fault codes are displayed in Red color and are displayed on the Gen 3 operator screen To further identify the fault (via the Gen 3_ITC Display), enter the Menu System, then select System Faults. This will display a list of the current system ...
    • Gen3_ITC - Fault Code - IT05

      This fault code can appear when the Gen 3 ITC is not able to write to the SD card. There are two common causes for this error code: 1. Write Lock Tab on the SD card has been set to 'Locked'. 2. SD card carrier in the EQSS Display unit is faulty. ...
    • Gen3_ITC - Fault Code - IT09

      This fault code can appear with a fresh Gen 3 install or when a CCIM has been replaced. The EQSS CCIM uses PCB mounted DIP switch banks for forward/reverse ITC drive logic settings. These settings are configured at the factory and can be ITC ...
    • Gen3_ITC - Fault Code - IT02

      The EQSS Gen 3 ITC kit contains a sensor that monitors the vehicle articulation angles The Gen 3 articulation angle sensor is used by the EQSS system to gather vehicle articulation data as part of the machine's weight lift capacity calculations. If a ...
    • Gen3_ITC - Fault Code - IT01

      Boom Angle is calibrated during the initial kit install The Boom Angle Sensor is used to determine the inclination of the boom relative to the initially calibrated machine angle. The IT01 fault code signifies: Boom Angle Out of Range The boom angle ...