Gen3_ITC - Fault Code - IN03

Gen3_ITC - Fault Code - IN03

Notes
The CDAM (Angle Sensor) Module is a CAN bus device 

If an IN03 fault code is displayed then there is a communication error between the CPIM module and the CDAM (Angle Sensor). The IN03 fault code indicates that the CDAM is Off-line and can't be seen by the rest of the CAN bus devices.
  1. Ensure the cable running along the boom with the 4-Pin circular connectors from the CPIM to the CDAM is fastened and secured on both ends of the cable.
  2. Inspect the cable for possible damage.
  3. Replace the CDAM 
  4. Make sure that the 4-Pin sockets pins are not bent within the sockets
Info
If you suspect a faulty CDAM module then contact EQSS for further guidance