Gen3_ITC - Fault Code - IT03

Gen3_ITC - Fault Code - IT03

Notes
The carrier angle sensors are situated in the Gen 3 CPIM
Causes for the IT03 fault code:
  1. Lateral Angle Out of Range
  2. The lateral angle has exceeded the defined range.
Troubleshooting:
The carrier angle is calibrated when the Gen 3 system is first installed. The carrier angle data can be lost if an EQSS module has been replaced.

First verify the carrier angle functionality. Tilt the carrier (vehicle) left/right and ensure the lateral angle is changing. If the lateral angle is changing, re-calibrate the carrier angle (described below). If the angle does not change, replace the CPIM or raise a support request and send the faulty CPIM to EQSS for repair.  

If the lateral angle is changing, the remedy that usually clears this fault is the re-calibration of the carrier angle. Achieving this task requires the operator to navigate the Gen 3 menu system to the 'Calibrate Carrier Angle' function screen.

The navigation path from the Gen 3 main screen is: 
1. Press the center 'Enter' button on the 5 button user control
2. Navigate to the 'System Menu'
3. Navigate to the 'Advanced Menu'
4. Enter Password '2  -  8  -  4' and then 'Submit Password'
5. Navigate to the 'Sensor Calibrations'
6. Navigate to the 'Calibrate Carrier Angle' function

Then read and execute the instructions on the display to complete the 'Calibrate Carrier Angle'

Navigate back to the Gen 3 main screen and the IT03 fault should have been cleared and no longer be displayed. If the IT03 fault remains then the CPIM may have developed an electronic fault and may require factory diagnosis/repair.
Alert
If the problem persists then contact EQSS support for further guidance.

    • Related Articles

    • Gen3_ITC - Fault Code - All Gen 3 Fault codes

      Gen 3 Fault codes are displayed in Red color and are displayed on the Gen 3 operator screen To further identify the fault (via the Gen 3_ITC Display), enter the Menu System, then select System Faults. This will display a list of the current system ...
    • Gen3_ITC - Fault Code - IT05

      This fault code can appear when the Gen 3 ITC is not able to write to the SD card. There are two common causes for this error code: 1. Write Lock Tab on the SD card has been set to 'Locked'. 2. SD card carrier in the EQSS Display unit is faulty. ...
    • Gen3_ITC - Fault Code - IT09

      This fault code can appear with a fresh Gen 3 install or when a CCIM has been replaced. The EQSS CCIM uses PCB mounted DIP switch banks for forward/reverse ITC drive logic settings. These settings are configured at the factory and can be ITC ...
    • Gen3_ITC - Fault Code - IT02

      The EQSS Gen 3 ITC kit contains a sensor that monitors the vehicle articulation angles The Gen 3 articulation angle sensor is used by the EQSS system to gather vehicle articulation data as part of the machine's weight lift capacity calculations. If a ...
    • Gen3_ITC - Fault Code - IT01

      Boom Angle is calibrated during the initial kit install The Boom Angle Sensor is used to determine the inclination of the boom relative to the initially calibrated machine angle. The IT01 fault code signifies: Boom Angle Out of Range The boom angle ...