Gen3_ITC - Installation - Volvo L120H & L90 CPIM Installation

The CPIM is responsible for processing the information sent from the pressure sensors, the
articulation sensor and the RFID sensor.
The CPIM also measures the chassis pitch and
roll with its internal angle sensors.
Installation Steps:
1. Drill two M8 holes for the CPIM
bracket in the position of the chassis (Shown in the diagram).
Ensure when marking mounting
location that there is enough room to
connect the cables.
Mount using the supplied
M8 bolts, nuts and washers.
2. Connect the cables for the pressure
sensors, Articulation sensor and
Angle sensors to the CPIM (according
to the picture shown below).
It would be beneficial to use a spirit level on top of the CPIM so that the CPIM module can be mounted square. This is helpful for when later on the sensor calibrations are completed.