Gen3 - Selections - Change and Store Machine Serial number

Gen3 - Selections - Change and Store Machine Serial number

Notes
The quickest method to change a machine serial number in Gen 3 display software
Changing a machine serial number in a Gen 3 requires a PC/Laptop, an SD card reader and the Windows 'Notepad' app. 
Steps to edit the relevant parameters:
1. Turn on and boot the computer
2. Insert the SD card from your telehandler into the card reader
3. On the SD card, locate the file:  data.cfg
4. On your PC, start the app: notepad.exe
5. Drag and drop data.cfg onto the open notepad page - image below represents some of what you will see.


6. The parameter that requires changes is the: 
MachineSerialNumber= 
A numerical value = will be entered/changed

7.  Make the changes as required:
Example: Changing the serial number from 43212 to 97989
1. Go to the end of the number - 2
MachineSerialNumber=43212
2. Backspace until the number is no longer seen via the PC keyboard

3. Enter your new number
MachineSerialNumber=97989




8. Save the changes by selecting File > Save


Select 'Save' to save the modified configuration



9. Eject the SD card and insert it back into the Gen 3 Display
When the Gen 3 next boots up, the machine serial number will be as edited in the data.cfg file.

Warning
Do NOT change any other parameters within the data.cfg file. Doing so may introduce gross inconsistencies and negate the Gen 3 abilities to be an effective safety system


    • Related Articles

    • Gen3 - General - Gen 3 Kits are Sold Machine Specific

      EQSS Gen 3 kits are Engineered, built, configured and sold as machine serial number specific orders The purpose for this Tech Doc is to briefly describe the Engineering Process that is implemented at EQSS for kits that will be fitted to recently ...
    • Gen3 - Installation - Generic Machine Electrical Connections

      To accommodate the various brands and many models, a substantial number of Gen 3 installation kits have been engineered and are available for purchase from EQSS. The following sections serve to illustrate common electrical connections from the Gen 3 ...
    • Gen3_ITC - Software - Change Between Automatic & Manual Tool Selection

      The EQSS ITC Gen 3 LMS system can be set to automatic attachment tool recognition or it can be set to manual When the Gen-3 system is configured for automatic tool selection, the system will read the identification tag on the attachment. The Gen 3 ...
    • Gen3 - Attachments - Change Between Automatic & Manual Tool Selection

      Changing settings via the display was added in Display Version 1129. Check the current display version in the Status Menu. If the version is older then follow the instructions here to update the display. Press Enter on the user control dial to enter ...
    • Gen3_ITC - General - What is a GEN 3 ITC?

      This system has been designed specifically for use with Integrated Tool Carriers (ITC) to cover all relative national and international safety standards. This Tech Doc details system specifications, system functionality, installation requirements, ...