OverWatch - Installation - Sensor Mounting Guard V2 (7.5 Degree Lateral Angle)
This guard (AS002326)
supersedes the original V1
design.
Some Overwatch installs require the sensor to be angled outwards (laterally away from the joystick) by 7.5 degrees. This sensor angling is accomplished by screwing the inner metal sensor carrier into the 7.5 degree offset hole (on the bottom of the main carrier bracket), such that it is twisted outwards from the joystick controller.
Mount the operator sensor (in the angle degree from the vertical position - as specified in the EQSS installation manual for your machine) on the mounting bracket using the supplied M5 washers and nuts. The installation manual for your particular EWP will give you the correct angle from the vertical that the sensor should be mounted and the correct locations where the holes should be drilled.
However, as a common rule of thumb, the sensor LIDAR should be aimed at the approximate height of an average operator chest height. Therefore, a little bit of common sense can be applied by installers of any EQSS Overwatch system. When the install has been completed, if the sensor is aimed above the operator's head (for example, when the operator is an arms length away from the EWP joystick controller) , then an error has been made by the installer and the Overwatch will not function as intended. If you find that the Overwatch isn't operating as expected, then please check your mounting holes and re-mount the sensor exactly as outlined in the EQSS install manual for your EWP.
The lateral 7.5-degree twist is
achieved by rotating the
sensor inside the assembly
and using the bolt hole as
show in the image.
Related Articles
OverWatch - Installation - Sensor Mounting Guard V2 (0 Degree Lateral Angle)
This guard (AS002326) supersedes the original V1 design. Some Overwatch installs require the sensor to be angled straight on at 0 degrees lateral. This sensor angling is accomplished by screwing the inner metal sensor carrier into the 0 degree ...
OverWatch - General - What is EQSS Overwatch and how does it work?
Principle of Operation The OverWatch™ is an innovative system designed as an aid to the operator. The system does not replace operator training. The system works on the premise of detecting the operator’s position and movements, with respect to the ...
Gen3 - Installation - System Test
The components now need to be tested to ensure everything has been properly installed and is functioning correctly. Power the system from the machine's ignition key switch. After about 10 seconds, the display will load with the boot screen and then ...
OverWatch - Installation - ECU modules are NOT Waterproof
EQSS first engineers a kit and then carefully document how best that kit should be installed (step-by-step) on specific EWPs. Problems occur when the EQSS installation manual is not followed. In particular, the Overwatch ECU must be mounted inside ...
SFPL - Installation - Sensor Calibration
Once the installation is complete, the sensors will require calibration. Sensors may also require re-calibration with other maintenance tasks (Display, SD card, Cable reeler replacement) Sensor calibration steps below: A sensor calibration must be ...