The OverWatch includes an embedded web server, accessible via Wi-Fi. This is disabled by default and each time the machine is powered down
The use of this interface is limited to
viewing the system’s diagnostic information, performing routine tests on all inputs/outputs and accessing
the
time stamped log files.The OverWatch does not connect to the internet and can not automatically exchange data or geographical location
to a server or another device
Minimum system requirements:
Any smart phone, tablet or laptop that meets the following requirements:
- The device can connect to a Wi-Fi access point
- The device has an up to date web browser installed (2019 onwards). Firefox on Android and Safari on Apple are essential
Enable Wi-Fi Connection:
The system’s Wi-Fi module is disabled by default. In order to enable Wi-Fi, the user must turn the machine on and allow the OverWatch to begin
boot-up until the green light is visible. Within 10 seconds of power up swipe the sensor three times.
After the Wi-Fi is enabled, the user may connect to the Wi-Fi network. Connect to the Wi-Fi network and enter the
generic access point password which is: 12345678
Accessing the Home Page:
Once the user’s Wi-Fi enabled device is connected to the OverWatch, open a web browser and enter the IP
address of the device’s internal web server 192.168.4.1
The following main page will be displayed:
WiFi Technical Specifications:
Operating Frequency Range | 2412 - 2484 MHz |
TX Power | 12 - 14 dBm |
Sensitivity | -98dBm |
Protocol | 802.11/b/g/n TCP/IP |
Data Rate | 150Mbps |
MAC Service | TX/RX A-MPDU |
Antenna Type | Omnidirectional |