SFPL - General - Maintenance

SFPL - General - Maintenance

The components of the SFPL require periodic checks and maintenance to be performed to ensure it remains in working order.
Cable Reeler Lubrication
The cable reeler consists of a multi core cable wrapped around a drum. As the boom extends, the cable unwinds from the drum. When the boom retracts, the cable winds back onto the drum. A cable guide prevents overlying of the cable. This ensures that the cable retracts uniformly onto the drum. Due to friction between the lays of wire and the layer guide, the cable may sag or catch during retraction. Therefore, regular lubrication of the cable is required. A regular inspection of the cable must be performed to ensure proper lubrication. The inspection interval will be dependent on the operating environment. To lubricate the cable, fully extend the boom. While retracting the boom spray a lubricant (RP7, WD40 or equivalent) onto the cable, until the boom is fully retracted. The cable must be lubricated at all times while the machine is in operation.

Sensor Calibration
As the SFPL is a safety device it's sensor calibration must be tested every 12 months or whenever changes have occurred to the man platform systems. The SFPL uses boom length and angle transducers to determine the current location of the boom. The variables in the system can change after a period of time due to a number of different factors, this may result in an incorrect boom location reading. A re calibration will readjust the location reading for any minor changes in the systems. If re calibration is required follow the instructions for the sensor calibrations 
The sensor calibrations must be tested every 12 months. An incorrect boom location reading may allow the boom to enter an unsafe location which could damage the man platform or cause injury.


    • Related Articles

    • SFPL - User - SFPL Menus

      The menu system allows for configuring and diagnosing the SFPL. To enter the menu system press the user control dial. This will display the main menu. To navigate through the menu options rotate the user control dial. The currently selected option ...
    • OverWatch - User - Inspection & Maintenance

      Regular maintenance must be performed on the OverWatch™ components to ensure the system operates correctly. This maintenance must be performed every 12 months in a rental situation, or before the machine is released to the hire customer.
    • Crush Guard - Maintenance - Service and Repairs

      The section will familiarize you with the components that comprise the Crush Guard® in order to perform a service or repair. The diagram below outlines the major system components and how they interconnect. Frame The frame is mounted to the front of ...
    • SFPL - Installation - Sensor Calibration

      Once the installation is complete, the sensors will require calibration. Sensors may also require re-calibration with other maintenance tasks (Display, SD card, Cable reeler replacement) Sensor calibration steps below: A sensor calibration must be ...
    • ITC SWL- Faults - Maintenance

      The components of the SWL safety system require periodic checks and maintenance to be performed to ensure it remains in working order. As the SWL is a safety device it's load calibration must be tested every 12 months or when ever changes have ...