Gen3 - Software - Update Configuration and Load Calibration for Barminco
Follow the instructions below to update the Gen3-LMS with the latest configuration and load calibrations.
- Remove the SD card from the Gen3 display and insert into a laptop
- Click on the links below that matches the machine
- Volvo L90H
- Volvo L120H
- Click the download icon in the top right and save the file to the SD card
Note: Do not save the update.tar file to the computer, always download from the links above to make sure the latest updates are applied. Change the default download behaviour of your browser to always ask where to download files, see below for instructions - Click Safely Remove Hardware from the system tray to safely remove the SD card from the laptop
- Insert the SD card into the Gen3 display
- Start the engine and the Gen3 display will load the update screen
- Wait for the update to finish and reboot to the main screen, then shutdown the machine
- Download and install Notepad++ from this link
- Remove the SD card from the Gen3 display and insert into a laptop
- Open the file data.cfg using Notepad++
- In the top [General] section update the following values
MachineSerialNumber=XXXX ; Change XXXX to the machine's serial number - Save the file
- Click Safely Remove Hardware from the system tray to safely remove the SD card from the laptop
- Insert the SD card into the Gen3 display
Do not edit anything else in the data.cfg except the lines as instructed above. Modifications to the Gen3 configuration files may cause the Gen3 to exhibit unknown or unpredictable behaviour negating the safety function.
Click the links below to change the browser default download behaviour to always ask where to download files so the update.tar file can be saved directly to the SD card
- Mozilla Firefox
- Google Chrome
- Microsoft Edge
Debug Update Problems
If the update process doesn't run after reinstalling the SD card back into the display, this is most likely caused by naming issues with the update.tar file.
After downloading the update.tar file to the SD card the windows file manager should look like below.
There should be no other files on the SD card except for update.tar
If the file only says update, you will also need to turn on file name extensions. In the windows file manager click View and select the checkbox File name extensions
Related Articles
Gen3 - Software - Update Barminco ITC Display Software
There are two versions of the ITC software for the Gen3-LMS. These instructions will apply the software for the Barminco range of machines. For all other ITC machines follow the Universal software instructions here. The following instructions will ...
Gen3 - Software - Update Universal ITC Display Software
There are two versions of the ITC software for the Gen3-LMS. These instructions will apply the Universal software. If the machine is owned by Barminco follow the instructions here. The following instructions will describe copying an update file to ...
Gen4 - Attachments - What is a Load Calibration?
The load calibration procedure will ask the operator to calibrate the load for the attachment. When the Gen 4 has an uploaded attachment load chart but no calibration information, then an attachment calibration must be performed. The ...
Gen3 - Attachments - What is a Load Calibration?
The load calibration procedure will ask the operator to calibrate the load for the attachment. When the Gen 3 has an uploaded attachment load chart but no calibration information, then an attachment calibration must be performed. The ...
Gen4 - Calibration - Load Calibration Tips
This Tech Doc will offer a few suggestions to follow in order to perform an accurate calibration. The points listed below are recommended to follow for each of the calibration steps. Make sure to lower the stabilizers (if fitted) and try to level the ...