Gen3 - Attachments - Update Existing Gen3-LMS for New Attachments
Adding a new attachment to an existing telehandler with a Gen3-LMS system requires an update to the model configuration.
To perform the update a laptop with an SD card reader and internet connection is required.
The below needs to be performed off-site when the laptop has an internet connection
Download EQSS Update software
- Go to http://www.eqss.com.au in a web browser
- Click on Login in the top menu
- Type in the user name and password for your company and click Log in (contact EQSS if you don't know your company username and password)
- Click on Secure Menu in the top menu
- Click on the link EQSS Update Software Download
- Click on the link Download EQSS Update software V 1.6, to start the setup program download
- Once the download is complete run the setup program to install the software
Download the latest model files using the EQSS Update software
- Run the EQSS Update software from Start Menu -> All Programs -> EQSS -> EQSS Update -> EQSS Update
- Enter the same username and password into the User and Pass fields
- Click on Check For Updates to list the available updates
- Any new updates will automatically be ticked in the Select Updates window
- Click on Download Updates to download and install the updates
Note: It may also start the install processes for other software updates, run through the prompts to install the software - Once the downloads/installations are complete click on Quit
The below needs to be performed on-site with access to the machine
The Gen-3 Configuration Tool user manual
here or installed under Start Menu -> All Programs -> EQSS -> Gen-3 Configuration Tool explains the Gen-3 Configuration Tool in more detail and shows how to remove the SD card from the display
- Remove the SD card from the Gen3 display and insert into the laptop
- Run the Gen-3 Configuration Tool from Start Menu -> All Programs -> EQSS -> Gen-3 Configuration Tool -> Gen-3 Configuration Tool
- Click on Select SD Card, it should bring up a message saying it has found the sd card on drive X: and click OK
- Click on the Machine Model tab at the top of the screen
- Select the model file from the list that matches the machine from the Change window
- If update is being performed to replace a load calibration then untick Keep existing load calibration data
- Click on Save Changes
- Click on the Attachments tab at the top of the screen
- Disable any attachments that aren't used with the machine, by selecting the attachment and clicking the Attachment Enabled checkbox
- Return to the SD Card tab
- Click on Save to SD Card, this will bring a popup message explaining how to finish the update, click on OK
- Click Safely Remove Hardware from the system tray to safely remove the SD card from the laptop
- Insert the SD card into the Gen3 display
- Start the engine to power the Gen3 LMS
- Open the Attachment Menu and ensure all the correct attachments are shown on the screen
On the Attachments tab, if the new attachment is not shown on the list contact EQSS to begin the new rating chart ordering process
On the Attachments tab, if the attachment is shown in red then a load calibration of the attachment will be required before it can be used.
If an non calibrated attachment is enabled and selected in the Gen3 it will display the following in place of the load reading on the display "Gen3 Load Measuring Disabled" and will not generate a cutout if overloaded.
Related Articles
Gen3 - General - What is Gen 3 LMS?
The Gen3-LMS is a culmination of the current research and development efforts conducted by EQSS. The main purpose of the Gen3-LMS is to provide an additional level of safety when lifting both suspended and non-suspended loads. It is in effect a ...
Gen3 - Software - Apply update file to Gen3-LMS
The following instructions will describe copying an update file to the Gen3-LMS SD card so that an update can be applied. Remove the SD card from the Gen3 display and insert into the laptop Note: The Gen-3 Configuration Tool user manual here explains ...
Gen3 - Attachments - Perform Attachment Calibrations
Calibration for attachments requires discipline, is time consuming and should be completed carefully. To carefully and properly complete an attachment calibration usually requires at least two hours of work. The attachment calibration task requires: ...
Gen3 - Installation - Generic Gen 3 LMS Schematics
The Schematics below can be used to help with diagnosing EQSS Gen 3 LMS wiring faults on a Telehandler Generic Gen 3 LMS Schematics
Gen4 - General - What is Gen 4 LMS?
Hardware Overview Display The Model 6205 Display Module is the main HMI device for the Gen4-LMS. It is used to display information to the operator. It contains a built in touch screen to allow the operator to interact with the system, and dual audio ...