Gen1 - Installation Deici Icarus 40.17 Gen 1 to Gen 3 - System Test
The Gen3 LMS system is now installed. The components now need to be tested to ensure everything has been properly installed and is functioning correctly. System Test Power the system from the machine's ignition key switch. After about 10 seconds the ...
Gen1 - Installation Deici Icarus 40.17 Gen 1 to Gen 3 - Machine Connections
This Tech Doc describes how to connect the safety system to the existing electronics in the machine Isolate the main battery before starting the machine connections Stabiliser Harness The stabiliser harness is a 6 meter long cable with a 2-Pin and a ...
Gen1 - Installation Deici Icarus 40.17 Gen 1 to Gen 3 - Display Installation
The display is the main indicator device for the Gen3 LMS system. It should be mounted in a location that is visible to the operator at all times, regardless of the steering wheel and/or seat position. The supplied GEN3 display bracket has been ...
Gen1 - Installation Deici Icarus 40.17 Gen 1 to Gen 3 - User Input Control
The user input control switch is used to navigate the menus in the Gen3 LMS The user input control should be mounted in the dashboard in a location that is usable and visible to the operator. Drill a 34 mm hole into the dashboard to mount the switch. ...
Gen1 - Installation Deici Icarus 40.17 Gen 1 to Gen 3 - CCIM Module
The CCIM connects the system into the machine electronics and interfaces between the display and the external sensors The CCIM along with the backup battery should be mounted inside the dashboard near the rest of the machine electronics. The CCIM and ...
Gen1 - Installation Deici Icarus 40.17 Gen 1 to Gen 3 - Camera Installations
The camera images are displayed on the screen when the machine is in drive The forward camera is displayed when in forward gear and the reverse camera is displayed when in reverse gear. Forward camera The main purpose of the forward camera is to ...
Gen1 - Installation Deici Icarus 40.17 Gen 1 to Gen 3 - CPIM Module Installation
The CPIM is responsible for processing the information sent from the pressure sensors and also measures the carrier attitude The CPIM should be mounted in the same location as the GEN1 ISM modules. Below: Remove GEN1 ISM Modules and Install GEN3 CPIM ...
Gen1 - Installation Deici Icarus 40.17 Gen 1 to Gen 3 - Signal Light Installation
The signal light warns other workers when the telehandler is lifting loads close to it's maximum capacity. The signal light has a magnet on the base and is designed to be magnetically mounted to the roof of the cabin. Alternatively, the signal light ...
Gen1 - Installation Deici Icarus 40.17 Gen 1 to Gen 3 - Pressure Sensor Installation
The hydraulic pressure sensors are used to measure the lifting load of the telehandler. There are two pressure sensors that need to be mounted to measure the pressure in the main lift cylinder. The pressure sensors from the GEN1 will need to be ...
Gen1 - Installation Deici Icarus 40.17 Gen 1 to Gen 3 - Cable Reeler Installation
The cable reeler contains the sensors required to measure the boom extension and boom angle to allow the Gen3 LMS to calculate the boom position. The GEN3 and GEN1 cable reelers are mechanically identical and can be directly swapped over. Use the ...
Gen1 - Installation Deici Icarus 40.17 Gen 1 to Gen 3 - Installation Outline
Installation Outline The diagram below outlines how the system components are connected for the Gen3 LMS. It is recommended to install the components in the following order: the external sensor components are mounted first, then the components inside ...
Gen1 - Software - Set to Manual Tool Selection
Your Gen1 Safety System Can Operate On Manual Tool Selection To enable Manual tool selection. 1. Remove the Compact Flash Dist from the display and open the disk on a computer 2. Open the folder CONFIG 3. Inside this folder there is a file called ...
Gen1 - Software - MPCT Calibrator Software
Your Gen 1 Safety System must be calibrated using a laptop and EQSS calibration software before being put into service The MPCT Software is to be loaded on a laptop and is broken down into seven calibration sections and one configuration section. ...
Gen1 - User - Quick Reference Guide
The Quick Reference Guide is included as a sticker - on the side glass in the cabin.
Gen1 - User - Troubleshooting
Troubleshooting Common EQSS Gen 1 Problems Problem: The boom won't move and the stop icon is showing on the display Solution: You are trying to lift a load which is greater than the maximum capacity specified by the manufacturer rating charts for ...
Gen1 - User - Attachment Identification
The TSS is able to determine the current attachment using an ID reader located on the quick release and ID tags located on the attachments. This means attachments can be quickly and easily exchanged without having to connect anything at the end of ...
Gen1 - User - Understanding The Display
The TSS display consists of a multitude of display symbols which indicate the current state of the machine in real time. Below is a description of the layout and symbols. Display Symbols Attachment Symbols The attachment symbols are located in the ...
Gen1 - Maintenance - Lubrication and Calibration
Cable Reeler Lubrication The cable reeler consists of a multi core cable wrapped around a drum. As the boom extends, the cable unwinds from the drum. When the boom retracts, the cable winds back onto the drum. A cable guide prevents overlying of the ...
Gen1 - User - Man Platform Operations
When the man platform has been attached to the telehandler, the range of movement is limited to 3 meters height and 5 meters radius while the stabilizers are up. If these limits are exceeded the cutout will engage. The cutout generated for a man ...
Gen1 - User - Rated Capacity Limiter Range
The TSS will not engage the cut-out limit while the boom extension is less than 1 meter and the boom angle is less than 10 degrees (as per Australian Standard AS1418.19- 2007 Section 2.11.3.3 (b)). The graphs below shows the rated capacity limiter ...
Gen1 - User - Cut Out
Cut-out Operation When the cut-out is engaged, the general stop indicator will show on the display. If the LED bar graph is unlit when the cut-out is engaged; this indicates that the currently identified attachment can't be used in this ...
Gen1 - User - Visual and Audio Warning States
The table below outlines the visual and audio warnings for each operating state. Once the capacity exceeds 100% and the cut-out is engaged, the cut-out will not disengage until the capacity is below 95%.
Gen1 - Maintenance - Use of Silicon Grease
Silicon grease must be applied to the pins of each connector. This prevents moisture entering the connectors which causes: ● voltage fluctuations - sending incorrect sensor readings to the system ● rust on the pins - a rusty pin can not conduct ...