Model6245 Gen1
Gen1 - Software - Set to Manual Tool Selection
Your Gen1 Safety System Can Operate On Manual Tool Selection To enable Manual tool selection. 1. Remove the Compact Flash Dist from the display and open the disk on a computer 2. Open the folder CONFIG 3. Inside this folder there is a file called ...
Gen1 - Software - MPCT Calibrator Software
Your Gen 1 Safety System must be calibrated using a laptop and EQSS calibration software before being put into service The MPCT Software is to be loaded on a laptop and is broken down into seven calibration sections and one configuration section. ...
Gen1 - User - Quick Reference Guide
The Quick Reference Guide is included as a sticker - on the side glass in the cabin.
Gen1 - User - Troubleshooting
Troubleshooting Common EQSS Gen 1 Problems Problem: The boom won't move and the stop icon is showing on the display Solution: You are trying to lift a load which is greater than the maximum capacity specified by the manufacturer rating charts for ...
Gen1 - User - Attachment Identification
The TSS is able to determine the current attachment using an ID reader located on the quick release and ID tags located on the attachments. This means attachments can be quickly and easily exchanged without having to connect anything at the end of ...
Gen1 - User - Understanding The Display
The TSS display consists of a multitude of display symbols which indicate the current state of the machine in real time. Below is a description of the layout and symbols. Display Symbols Attachment Symbols The attachment symbols are located in the ...
Gen1 - Maintenance - Lubrication and Calibration
Cable Reeler Lubrication The cable reeler consists of a multi core cable wrapped around a drum. As the boom extends, the cable unwinds from the drum. When the boom retracts, the cable winds back onto the drum. A cable guide prevents overlying of the ...
Gen1 - User - Man Platform Operations
When the man platform has been attached to the telehandler, the range of movement is limited to 3 meters height and 5 meters radius while the stabilizers are up. If these limits are exceeded the cutout will engage. The cutout generated for a man ...
Gen1 - User - Rated Capacity Limiter Range
The TSS will not engage the cut-out limit while the boom extension is less than 1 meter and the boom angle is less than 10 degrees (as per Australian Standard AS1418.19- 2007 Section 2.11.3.3 (b)). The graphs below shows the rated capacity limiter ...
Gen1 - User - Cut Out
Cut-out Operation When the cut-out is engaged, the general stop indicator will show on the display. If the LED bar graph is unlit when the cut-out is engaged; this indicates that the currently identified attachment can't be used in this ...
Gen1 - User - Visual and Audio Warning States
The table below outlines the visual and audio warnings for each operating state. Once the capacity exceeds 100% and the cut-out is engaged, the cut-out will not disengage until the capacity is below 95%.
Gen1 - Maintenance - Use of Silicon Grease
Silicon grease must be applied to the pins of each connector. This prevents moisture entering the connectors which causes: ● voltage fluctuations - sending incorrect sensor readings to the system ● rust on the pins - a rusty pin can not conduct ...