Gen3_ITC - Fault Code - IN08

Gen3_ITC - Fault Code - IN08

Notes
This fault code can appear when there is a problem with the Pressure 1 Sensor or the Pressure 1 CPIM Port or the sensor cable.

 There are 3 likely reasons that this fault may appear: 
1. Cable problem
2. Sensor problem
3. Connector loose inside the CPIM

1. Cable Problem - Investigations
* Check for cuts or breaks in the cable
* Check for damage inside each 4 pin screw connector
* With a continuity tester, check continuity of each cable run between the cable connectors
* Check that the screw connectors are screwed in tight at both the CPIM connector and the Sensor connector

2. Sensor Problem - Investigations
* If a spare sensor is available then try replacing the Compensation Rod Pressure Sensor
* If a spare sensor isn't available then try swapping with a different sensor in the system and see if the fault follows the sensor


3. Connector loose inside the CPIM - Investigations
Warning
We don't encourage customers to open the CPIM as that action may compromise the water seal integrity of that unit.

*  However, as a last resort, unscrew the 4 screws of the CPIM and re-seat the Pressure 1 sensor connector on the PCB.
Alert
Make sure that during re-assembly, the CPIM rubber gasket is properly aligned and the screws are properly tightened


Info
If the problem still persists, contact support at EQSS for further guidance

    • Related Articles

    • Gen3_ITC - Fault Code - All Gen 3 Fault codes

      Gen 3 Fault codes are displayed in Red color and are displayed on the Gen 3 operator screen To further identify the fault (via the Gen 3_ITC Display), enter the Menu System, then select System Faults. This will display a list of the current system ...
    • Gen3_ITC - Fault Code - IT05

      This fault code can appear when the Gen 3 ITC is not able to write to the SD card. There are two common causes for this error code: 1. Write Lock Tab on the SD card has been set to 'Locked'. 2. SD card carrier in the EQSS Display unit is faulty. ...
    • Gen3_ITC - Fault Code - IT09

      This fault code can appear with a fresh Gen 3 install or when a CCIM has been replaced. The EQSS CCIM uses PCB mounted DIP switch banks for forward/reverse ITC drive logic settings. These settings are configured at the factory and can be ITC ...
    • Gen3_ITC - Fault Code - IT02

      The EQSS Gen 3 ITC kit contains a sensor that monitors the vehicle articulation angles The Gen 3 articulation angle sensor is used by the EQSS system to gather vehicle articulation data as part of the machine's weight lift capacity calculations. If a ...
    • Gen3_ITC - Fault Code - IT01

      Boom Angle is calibrated during the initial kit install The Boom Angle Sensor is used to determine the inclination of the boom relative to the initially calibrated machine angle. The IT01 fault code signifies: Boom Angle Out of Range The boom angle ...