Gen3_ITC - Installation - Caterpillar 962K EQSS CPIM Installation

Gen3_ITC - Installation - Caterpillar 962K EQSS CPIM Installation

Notes
The CPIM is responsible for processing the information sent from the pressure sensors the articulation sensor and the RFID sensor
The CPIM also measures the chassis pitch and roll with its internal angle sensors. 
Installation Steps:
1. The location of the CPIM is shown in the image below (within the red circle).


2. Drill two M8 holes for the CPIM bracket in the position of the chassis (Shown in the photo below).
3. Ensure when marking mounting location that there is enough room to connect the cables.
4. Mount using the supplied M8 bolts, nuts and washers.


5. Connect the cables for the pressure sensors, Articulation sensor and Angle sensors to the CPIM (as shown in the photo below).


Info
Accidentally swapping the pressure sensor connections will not damage the system
Warning
Do not plug the pressure sensor cable into the far right side boom cable. This will damage the system.