Crush Guard - Service - Genie ALC500/ALC1000 User Interface

Crush Guard - Service - Genie ALC500/ALC1000 User Interface

Notes
The purpose of this Tech Doc is to help with the Servicing of the User Interface

User Interface
The user interface is mounted to the frame and contains status lights as well as an override switch. It is connected to the control module using an M12 cable.

Damage to User Interface
If the user interface has been damaged from an impact causing a breach of the enclosure or damage to the override switch or the cable, then the user interface will need to be replaced. The user interface enclosure including the cable is a self contained unit with no replaceable parts.

Follow the instructions below to replace the user interface.

Replace User Interface
Once the replacement user interface has been ordered and received follow the instructions below to swap out the user interface.
1. Disconnect the cable from the user interface into the control module
2. Cut any cable ties and remove the rope switch cable from the snake tubing
3. Remove the cable from the p-clip, by removing the bolts on the cover of the User Interface enclosure, to access the bolt attached to the p-clip
4. Remove the remaining bolts attaching the user interface enclosure to the frame
5. Remove the bolts attaching the cover of the replacement user interface
6. Secure the replacement user interface to the frame using the existing bolts
7. Run the cable through the p-clip and reattach the p-clip to the existing location
8. Reattach the user interface cover
9. Run the cable through the snake tube, reconnect to the control module
10. Secure using cable ties 















    • Related Articles

    • Crush Guard - Service - Genie ALC500/ALC1000 Machine Interface

      The purpose of this Tech Doc is to help with servicing the Machine Interface The machine interface is a M23 connector harness integrated into the EWP electronics (inside the control box). Damage to Machine Interface Wiring If the machine interface ...
    • Crush Guard - Service - Genie ALC500/ALC1000 Frame Structure

      The purpose of this Tech Doc is to help with the Servicing of the frame structure Frame The frame is mounted to the front of the EWP and runs a steel wire rope in front of the EWP controls. When the operator leans on the wire rope the alarm will ...
    • Crush Guard - Service - Manitou 160ATJ/180ATJ/200ATJ User Interface

      The purpose of this Tech Doc is to help with the Servicing of the User Interface The user interface is mounted to the frame and contains status lights as well as an override switch. It is connected to the control module using an M12 cable. Damage to ...
    • Crush Guard - Service - Genie ALC500/ALC1000 Replace Fuse

      The purpose of this Tech Doc is to help with replacing the fuse The crush guard contains a single 1A standard blade fuse inside the control module enclosure. Follow the instructions below to test or replace the fuse: 1. Disconnect the M12 cables from ...
    • Crush Guard - Maintenance - Service and Repairs

      The section will familiarize you with the components that comprise the Crush Guard® in order to perform a service or repair. The diagram below outlines the major system components and how they interconnect. Frame The frame is mounted to the front of ...