Gen3_ITC - Installation - Caterpillar 962K External Cable Completion

The completion of the external cabling is outlined in this Tech Doc
Installation Steps:
1. Locate the CCIM cable then locate the cabin entrance grommet (found at the front end of the cabin).
Run the CCIM, cutout and camera
cable up through the hole into the
cabin under the foot pedals.
Note: Pull the entire length of cable
through into the cabin, excess cable
will be stored beneath the side
console.
2. Connect the CCIM cable to the side
of the CPIM (red circle in the photo below).
3. Machine Cutout
Locate the solenoid PWM9101 ‘Lift
arms up solenoid’ which is situated
underneath the machine close to the
centre of the two front tyres.
Note: The boom cannot be lifted
until the rest of the installation has
been completed.
4. Unplug the existing two-pin
connector and replace it with the
one end of the T-connector, with
the other end of the connector
connecting to the existing cable.
Related Articles
Gen3_ITC - Installation - Volvo L120H & L90 External Cable Completion
All external cabling is completed in this section Installation Steps: 1. Locate the reverse camera cable, CCIM cable and Machine cutout cable and 6-core video cable. Locate the cabin entrance grommet located at the front end of the cabin. 2. Run the ...
Gen3_ITC - Installation - Caterpillar 962K Signal Light Installation
The signal light warns other workers when the ITC is lifting loads close to it's maximum capacity Installation Steps: 1. Drill and tap four M4 holes to mount the signal light bracket to the left side of the cabin roof (location shown in the photo). ...
Gen3_ITC - Installation - Caterpillar 962K Pressure Sensor Installation
The hydraulic pressure sensors are used to measure the lifting load of the ITC Main Cylinder Installation Steps: 1. Raise the boom to approximately 40 degrees. Support and secure the boom using an A Frame or similar apparatus. It must support at ...
Gen3_ITC - General - What is a GEN 3 ITC?
This system has been designed specifically for use with Integrated Tool Carriers (ITC) to cover all relative national and international safety standards. This Tech Doc details system specifications, system functionality, installation requirements, ...
Gen3_ITC - Installation - Caterpillar 962K Display Installation
The display shows the current safety status of the ITC Installation Steps: Position the display bracket at the top left of the Switch Column. Drill two M6 holes to attach the bracket to the Switch Column. Secure the bracket to the switch column using ...