When the man platform has been attached to the telehandler, the range of movement is
limited to 3 meters height and 5 meters radius while the stabilizers are up.
If these limits
are exceeded the cutout will engage.
The cutout generated for a man platform is not an aggravated movement cutout, but is
similar to a height limit cutout. The cutout prevents raising or extending the boom, but
the operator can still lower or retract the boom.

The man platform cutout can not be
overridden with the override key.
When the telehandler has been moved into position and the outriggers have been
lowered, the cutout will engage - preventing the man platform from being raised. Further
boom movements must be performed from the man platform controls.
When the key selector switch (P221) is set to man platform, the EQSS safety system
relies on the man platform's load cell to determine when it is overloaded. The display
will show the current load to an observer in the cabin and the light tower will operate as
normal. However, the alarm will not sound and the cutout will not engage. The Free
Operation Mode icon will be shown on the display.
Key Selector Switch (P221)
Related Articles
Gen3_ITC - Installation - Volvo L120H Man Platform Cameras Installation
The Man Platform camera’s are displayed on the screen when the Man Platform is connected. Installation Steps: 1. Feed approximately 2m of the cable with the 6 pin connector side from the outside through the cabin entry grommet. 2. Route the cable ...
OverWatch - User - WiFi Access
The OverWatch includes an embedded web server, accessible via Wi-Fi. The use of this interface is limited to viewing the system’s diagnostic information, performing routine tests on all inputs/outputs and accessing the time stamped log files. Minimum ...
Gen3_ITC - General - What is a GEN 3 ITC?
This system has been designed specifically for use with Integrated Tool Carriers (ITC) to cover all relative national and international safety standards. This Tech Doc details system specifications, system functionality, installation requirements, ...
Gen1 - User - Troubleshooting
Troubleshooting Common EQSS Gen 1 Problems Problem: The boom won't move and the stop icon is showing on the display Solution: You are trying to lift a load which is greater than the maximum capacity specified by the manufacturer rating charts for ...
OverWatch - User - Session Auto Calibration
The OverWatch starts sensing the operator from the time the platform’s dead-man trigger is pressed. When the machine is powered, and the system is functional, the operator will see a green light on the OverWatch sensor. This indicates that the ...