Gen3_ITC - Installation - Caterpillar 962K Articulation Sensor Installation

The articulation sensor is mounted mid machine at the point of machine articulation
Installation Steps:
1. Install the Articulation base plate in
the location shown (red circle in the left photo below).
Make sure the inner circle from the
Articulation Bracket Base Plate
matches up with pivot point of the
machine.
Modification to the articulation
bracket base will be necessary in
order to make the bolts align.
The articulation angle bracket arm
will need to be modified and welded
in the location shown in the bottom
image. Use the supplied screws to
adjust the distance accordingly.
2. Once the Core Bracket has been
mounted, align the sensor bracket
arm in such way that the core sits
over the designated location on the
sensor.
The sensor has a small circular
groove where the core must sit. The
distance between the core and the
sensor must be no greater than
5mm.
Once aligned, mark the mounting
location for the ‘Sensor Bracket
Arm’ and weld in the marked
location
3. Route the Sensor cable as shown in
the diagram, use cable ties to
attached the Sensor cable to the
existing flexible pipes and avoid
contact with other moving objects.
The cable will need to be routed to
the articulation port on the CPIM.
Articulation Sensor Components

Some machines had wiring modifications applied by the end user and may not match the wiring in this Tech Doc