Gen3_ITC - Installation - Volvo L120H Articulation Sensor Assembly Details
Articulation Sensor Assembly
Related Articles
Gen3_ITC - Installation - Volvo L120H Articulation Sensor Installation
The articulation sensor is mounted mid machine at the point of machine articulation Installation Steps: 1. Drill two M6 holes for the Articulation base plate in the location shown, using the plate as a guide to mark the M6 hole locations. Make sure ...
Gen3_ITC - Installation - Volvo L120H Main Head & Rod Pressure Sensors
The hydraulic pressure sensors are used to measure the lifting load of the ITC Installation Steps: Completely lower the boom. Apply the handbrake and insert chock under wheels. Once lowered, release any residual pressure by pulling on the manual ...
Gen3_ITC - Fault Code - IN09
The ITC machines use an articulation sensor to monitor the articulation of the vehicle The following are possible reasons for an IN09 fault code: CPIM Articulation Fault The 'articulation angle sensor' is not recognised. Example below: Volvo ITC ...
Gen3_ITC - General - What is a GEN 3 ITC?
This system has been designed specifically for use with Integrated Tool Carriers (ITC) to cover all relative national and international safety standards. This Tech Doc details system specifications, system functionality, installation requirements, ...
Gen3_ITC - Installation - Volvo L120H Boom Angle Sensor Installation
The Boom Angle Sensor is used to determine the inclination of the boom relative to the initially calibrated machine angle. Installation Steps: 1. Drill two M6 holes for the Angle Sensor in the position on the arm Shown in the diagram. 2. Mount the ...