The articulation sensor is mounted mid machine at the point of machine articulation Installation Steps: 1. Drill two M6 holes for the Articulation base plate in the location shown, using the plate as a guide to mark the M6 hole locations. Make sure ...
The articulation sensor is mounted mid machine at the point of machine articulation Installation Steps: 1. Install the Articulation base plate in the location shown (red circle in the left photo below). Make sure the inner circle from the ...
The hydraulic pressure sensors are used to measure the lifting load of the ITC Installation Steps: Completely lower the boom. Apply the handbrake and insert chock under wheels. Once lowered, release any residual pressure by pulling on the manual ...
The Boom Angle Sensor is used to determine the inclination of the boom relative to the initially calibrated machine angle. Installation Steps: 1. Drill two M6 holes for the Angle Sensor in the position on the arm Shown in the diagram. 2. Mount the ...
The ITC machines use an articulation sensor to monitor the articulation of the vehicle The following are possible reasons for an IN09 fault code: CPIM Articulation Fault The 'articulation angle sensor' is not recognised. Example below: Volvo ITC ...